MPS Techno Fab is leading 120 Minute Fire Rated Door Manufacturers, Suppliers, Dealers and Exporters in Pune, Maharashtra. A 120 minute fire rated door is a specialized fire-protection assembly designed to provide a specified level of resistance to fire for up to 120 minutes when tested under the applicable standard. These doors are used where building design requires higher levels of fire separation.
Fire-rated doors are commonly installed in industrial facilities, commercial buildings, hospitals, high-rise structures, utility areas, electrical rooms, staircases, plant rooms, and other locations where openings need to maintain compartmentation.
The performance of a fire door depends on more than the door leaf alone. The frame, hinges, locking hardware, seals, insulation, glazing where applicable, fixing method, and surrounding wall construction must be suitable for the intended fire-resistance classification.
A 120 minute fire rated door is a tested door assembly intended to provide fire resistance for a specified period of 120 minutes under the applicable test conditions. It is designed to help restrict the spread of fire and heat between separated areas.
The assembly may consist of a steel door leaf, fire-resistant core, steel frame, hinges, latch or lock, intumescent seals, smoke seals, and other approved components. The exact construction depends on the manufacturer's tested configuration.
Under normal conditions, the door provides controlled movement between two areas and remains closed or is held open only when an approved arrangement permits it. During a fire, the door and its components work together to maintain the required separation.
Fire-resistant materials help resist heat transmission, while perimeter seals can expand or react to heat to reduce gaps around the door. The frame and hardware also contribute to the performance of the complete assembly.
A fire door should always be installed according to the tested configuration and manufacturer's instructions. Changing components or installation details without approval may affect the tested performance.
As we are leading 120 Minute Fire Rated Door Manufacturers in Pune, Maharashtra, our Types are designed to meet different application requirements and industry standards, including the following types:
As a trusted 120 Minute Fire Rated Door Suppliers in Pune, Maharashtra, we serve businesses across various industries that meet professional visual communication requirements.
| Parameter | Specification | Performance | Material/Component | Application |
|---|---|---|---|---|
| Fire Rating | 120 minutes, as specified | Two-hour classification where tested | Fire-resistant door assembly | Protected openings |
| Door Leaf | Single or double construction | Rating dependent | Steel/metal with fire-resistant core | Commercial and industrial buildings |
| Frame | Matching fire-rated frame | Assembly dependent | Steel frame | Masonry or partition openings |
| Insulation | Fire-resistant core | Thermal protection | Mineral wool or approved material | Fire-rated doors |
| Seals | Intumescent/perimeter seals | Heat and smoke control | Approved fire-resistant seals | Door perimeter |
| Hardware | Hinges, locks, latches and closers | Duty and rating dependent | Steel/stainless-steel components | Regular access |
| Surface Finish | Powder coating or specified finish | Environment dependent | Coated steel | Indoor and industrial areas |
| Door Configuration | Single or double leaf | Opening dependent | Tested assembly components | Various building applications |
As 120 Minute Fire Rated Door Dealers in Pune, Maharashtra, our products provide several Features and Benefits including consistent quality, smooth finish, and long service life.
| Features | Benefits |
|---|---|
| Two-hour fire resistance | Supports extended fire compartmentation requirements |
| Steel construction | Provides strength and durability |
| Fire-resistant core | Helps reduce heat transfer through the door assembly |
| Intumescent seals | Helps close perimeter gaps when exposed to heat |
| Robust hardware | Supports reliable opening and closing |
| Single and double configurations | Provides flexibility for different opening sizes |
| Custom dimensions | Allows adaptation to project requirements |
| Protective finishes | Helps improve durability and surface protection |
A 120 minute fire rated door certification provides documentation associated with the tested performance of a particular door assembly. The certification should be reviewed to confirm the tested construction, dimensions, rating, hardware, installation method, and other relevant conditions.
A 120 minute fire door test certificate can provide evidence of the fire performance achieved during the applicable test. Buyers should verify that the certificate corresponds to the actual product configuration being supplied.
For projects requiring Indian standards, a 120 minute fire door IS 3614 specification should be checked against the applicable requirements and current project documentation. The relevant standard and test evidence should be confirmed before final specification.
For projects referencing British standards, a 120 minute fire door BS 476 requirement should be evaluated according to the relevant part of the standard and the applicable test classification. The exact rating and test conditions should be verified from the product documentation.
Fire-resistance ratings should not be determined solely from the material thickness of a door. The complete assembly and installation arrangement are important to achieving the tested performance.
As 120 Minute Fire Rated Door Exporters in Pune, Maharashtra, our all types are used in various types of industrial sectors such as:
Correct installation is essential for achieving the intended performance of a fire-rated door. The frame should be correctly aligned and securely fixed, while the required seals, hinges, hardware, and closing mechanism should be installed according to the approved configuration.
The surrounding wall should also be suitable for the specified fire-resistance requirement. Gaps around the frame should be treated according to the approved installation method rather than filled with unapproved materials.
Regular inspection should check the condition of seals, hinges, closers, latches, locks, frame fixings, and door alignment. Damaged or modified components should be assessed before the door is returned to service.
As one of the leading 120 Minute Fire Rated Doors in Pune, Maharashtra, we deliver premium-quality solutions designed to meet diverse industrial requirements. Here's why we stand out:
MPS Techno Fab is leading 120 Minute Fire Rated Door Manufacturers, Suppliers, Dealers and Exporters in Pune, Maharashtra. A two-hour fire-rated door is an important component in building fire compartmentation where extended fire resistance is required. Its effectiveness depends on the complete assembly, including the door leaf, frame, fire-resistant core, seals, hardware, and correct installation.
Selecting a suitable door requires consideration of the required rating, opening dimensions, wall construction, access frequency, hardware, applicable standards, certification, and installation conditions.
For industrial plants, commercial buildings, hospitals, high-rise structures, electrical rooms, warehouses, and infrastructure projects, a properly specified fire-rated door can provide controlled access while supporting the building's overall fire-safety strategy. Contact us today to discuss your fire-rated door requirements and get a suitable project-specific solution.
It refers to the specified fire-resistance period achieved by a tested door assembly under applicable test conditions. The exact performance depends on the complete tested configuration.
Yes. Custom dimensions can be considered depending on the tested construction, opening size, door configuration, hardware, and project requirements.
Yes. Double-leaf configurations can be used for wider openings, provided the complete assembly—including leaves, frame, seals, and hardware—is designed and tested for the required rating.
Yes. The frame is an integral part of the door assembly and should be compatible with the required fire-resistance classification and tested configuration.
Inspection frequency depends on building use, local requirements, door usage, and maintenance procedures. Regular checks should identify damage, misalignment, worn seals, or hardware problems.